HIGH-PERFORMANCE OPTICAL MEASUREMENT EQUIPMENT AND SYSTEM SOLUTION

OPTICS AND OPTICAL MEASUREMENT INSTRUMENTS

HIGH RESOLUTION FFP MEASUREMENT OPTICS FOR IR RANGE M-Scope type FHR

PRODUCT OVERVIEW

mscopetypefhr

M-Scope type FHR is an optical system for measuring FFP in 1310~1550nm NIR spectral range with high accuracy. The combination with VGA Type InGaAs High Sensitivity NIR Detector ISA041VH enables high-accuracy FFP measurement with an angle pixel resolution of 0.1° in 1310~1550nm spectral range.

It can be applied to high precision FFP measurement and N.A. measurement of various optical devices in optical communication fields such as optical fibers, optical waveguides, optical modules, and Si photonics devices.

It is possible to build high precision FFP measurement system in combination with SYNOS' Optical Beam Analysis Module AP013.

FEATURE

  • Specially designed optics for realtime observation and analysis FFP (Far Field Pattern) in IR range
  • Realize high angle pixel resolution of approx. 0.1° in 1310~1550nm wavelength range
  • Realize wide angle coverage of approx. ±32° × ±25.6° in 1310~1550nm wavelength range
  • Long working distance design of approx. 6mm
  • VGA Type InGaAs High Sensitivity NIR Detector ISA041VH is adopted as the designated detector

APPLICATION

  • FFP, N.A. measurement of infrared laser devices and optical modules
    • 1310nm~1550nm IR laser diodes for optical communication
    • Optical fibers
    • Optical waveguides
    • Si photonics devices
    • Various optical modules for optical communication

SUMMARY OF SPECIFICATION

MAIN SPECIFICATION OF THE OPTICS
Measurement method Dedicated f-θ lens optics and image processing method
Measurement light flux diameter approx. 1mmφ
Measurement wavelength 1310-1550nm wavelength range
Working distance approx. 6mm±0.8mm
Optical attenuation method By neutral density filters
Camera mount C mount
Measurement angle coverage Detector Measurement angle coverage Measurement wavelength
ISA041VH approx. ±32°(H)× ±25.6°(V) 1310-1550nm
Pixel resolution Detector Pixel resolution Measurement wavelength
ISA041VH approx. 0.1° 1310-1550nm

SIMPLE STRUCTURE OF HIGH RESOLUTION FFP MEASUREMENT OPTICS FOR IR RESION M-Scope type FHR

As shown in the figure on the left, the light flux, having incident angle θ from the sample, is focused at a point on the detector through f-θ lens, field lens and relay lens module. By this way, FFP image of the sample is formed and acquired by imaging detector, and analyzed directly and quickly by image processing method.

COMPONENT

STANDARD COMPONENT
  • M-Scope type FHR (optics unit) : 1set
  • Base plate for optics : 1set
OPTION
  • DETECTOR
  • Neutral density filter
    • IR ND Filter Set NDF IR-5
      • About neutral density filters, please refer to here.
  • Optics workbench for sample measurement
    • Optics Bench For Fiber Measurement OP002-F3/OP002-F5
    • Vertical Type Optics Bench OP002
      • About optics workbench, please refer to here.

RELATED PRODUCTS INFORMATION

SYSTEM SOLUTION / DATA PROCESSING AND ANALYSIS SYSTEM
  • FFP Measurement System
    • IR FFP measurement and analysis system in combination with High Resolution FFP Measurement Optics For NIR Range M-Scope type FHR and Optical Beam Analysis Module AP013.
  • Optical Beam Analysis Module AP013
    • Data acquisition and analysis system for optical beam analysis. AP013 is composed of a personal computer for data acquisition and data analysis, SYNOS' Optical Beam Analysis Software Optometrics BA Standard, camera driver software, and calibration data set.
OTHER OPTICS FOR OPTICAL MEASUREMENT

CATALOG DOWNLOAD